Short-Circuit Analysis of the Saparua Distribution Feeder Network

  • Elisabeth Tansiana Mbitu Politeknik Negeri Ambon
  • Marselin Jamlaay Politeknik Negeri Ambon
  • Ferdiaztha Rendy Sahusilawane Politeknik Negeri Ambon
Keywords: Short Circuit; Feeder; Fault and Current.

Abstract

Short-circuit faults are a type of disturbance that impedes the transmission of electrical energy. To protect equipment from the impact of such faults, short-circuit analysis is conducted. In this study, the magnitudes of phase-to-phase and phase-to-ground short-circuit currents are calculated, along with the determination of overcurrent relay and circuit breaker ratings on the distribution network of PT PLN Saparua Rayon, Maluku. The analysis is carried out using ETAP software on generator busbars and feeders at various fault locations. PT PLN (Persero) Saparua Rayon operates four feeders: Saparua, Pohar, Tenggara (Southeast), and Hatawano. Simulation results show that the Saparua feeder has the highest fault current at bus 6 under an L-L-G fault condition, while the Tenggara, Hatawano, and Pohar feeders exhibit their highest fault currents at the generator bus under an L-G fault. It is evident that the L-L-G (double line-to-ground) fault consistently generates the highest short-circuit current when compared to other types of faults such as L-L (line-to-line) and three-phase faults. This type of fault involves a direct connection between two phases and the ground, resulting in a larger fault current due to lower overall impedance at the fault point. Furthermore, it was observed that the magnitude of the short-circuit current decreases progressively with increasing distance from the power source. This behavior is primarily due to the increase in line impedance along the distribution path, which naturally limits the fault current as it travels farther from the generation point. In summary, the farther the location of the fault from the generator, the lower the resulting short-circuit current, which highlights the critical role of impedance in fault current behavior across the distribution network.

Downloads

Download data is not yet available.

References

Nugorho, D. T., Wardhana, A. W., & Wahyumi, A. (2020). Analisis koordinasi sistem proteksi penyulang Dieng-2 (dng02) terhadap gangguan arus hubung singkat Gardu Induk Dieng PT PLN (Persero) UP3 Purwokerto. Dinamika Rekayasa, 16(1), 69-82.

Duyo, R. A. (2020). Analisis Penyebab Gangguan Jaringan Pada Distribusi Listrik Menggunakan Metode Fault Tree Analysis Di Pt. Pln (Persero) Rayon Daya Makassar. Vertex Elektro, 12(2), 1-12.

Galla, W. F., Sampeallo, A. S., & Daris, J. I. (2020). Analisis Gangguan Hubung Singkat Pada Saluran Udara 20 Kv Di Penyulang Naioni Pt. Pln (Persero) Ulp Kupang Untuk Menentukan Kapasitas Pemutusan Fuse Cut Out Menggunakan Etap 12.6. Jurnal Media Elektro, 101-111.

Syah, F. R., Haryudo, S. I., Kartini, U. T., & Kholis, N. (2021). Analisis Hubung Singkat Pada Sistem Distribusi 20 Kv Pt. Pertamina Ep Asset 4 Field Cepu Distrik Ledok Menggunakan Etap 12.6. 0. Jurnal Teknik Elektro, 10(3), 699-706.

Agusthinus Sampeallo, N. P. (2019). Analisis Gangguan Hubung Singkat Pada Jaringan Pemakaian Sendiri Pltu Bolok Pt. Smse (Ipp) Unit 3 Dan 4 Menggunakan Software Etap 12.6.0. Media Elektro.

Al Asyad, A., Pujiantara, M., & Asfani, D. A. (2021). Evaluasi Kegagalan Koordinasi Proteksi akibat Hubung Singkat pada Kelistrikan PT Pertamina RU V Balikpapan. Jurnal Teknik ITS, 9(2), B14-B21.

Rizal, C., & Azis, A. (2022). Analisa Setting Relai Arus Lebih (OCR) Dan Relai Gangguan Tanah (GFR) Pada Penyulang Gurami Gardu Induk Sungai Kedukan Palembang. Jurnal Ampere, 7(1), 49-62.

Paminto, H. D., & Kiswantono, A. (2021). Rancang Simulasi Sistem Over Current Relay Pada Jaringan Distribusi 20KV. Aisyah Journal Of Informatics and Electrical Engineering (AJIEE), 3(1), 45-49.

Triyanto, A., & Agus Ulinuha, S. T. (2021). Analisis Gangguan Hubung Singkat Untuk Penentuan Breaking Capacity Circuit Breaker Pada Sistem Distribusi PLTD Di Pusat Pengembangan Sumber Daya Manusia Minyak Dan Gas Bumi Cepu (Doctoral dissertation, Universitas Muhammadiyah Surakarta).

Pauzan, A., Azis, A., & Febrianti, I. K. (2023). Analisa Penggunaan Recloser Untuk Memproteksi Arus Lebih Pada Jaringan Distribusi di PT. PLN (Persero) ULP Mariana Gardu Induk Prajin. Jurnal Surya Energy, 6(1), 17-24.

Published
2025-07-26
How to Cite
Mbitu, E. T., Jamlaay, M., & Sahusilawane, F. R. (2025). Short-Circuit Analysis of the Saparua Distribution Feeder Network . International Journal of Science, Technology & Management, 6(4), 608-615. https://doi.org/10.46729/ijstm.v6i4.1337
Section
Articles